ASTM A385 PDFASTM A385 PDF

ASTM A gives information on recommended steel chemistry for steel to be galvanized, as well as required venting/drainage hole. ASTM A/A M. Standard Practice for Providing High-Quality Zinc Coatings (Hot-Dip) provides details on steel selection and other design practices such as. ASTM Apdf – Download as PDF File .pdf), Text File .txt) or read online.

Author: Vomi Kazrabei
Country: Austria
Language: English (Spanish)
Genre: Love
Published (Last): 18 August 2015
Pages: 73
PDF File Size: 16.71 Mb
ePub File Size: 8.51 Mb
ISBN: 530-7-12693-683-2
Downloads: 73275
Price: Free* [*Free Regsitration Required]
Uploader: Faerg

A — 03 Standard Practice for Providing High-Quality Zinc Coatings Hot-Dip 1 This standard is issued under the fixed designation A ; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision.

Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Such uncoated surfaces cause a rust staining after exposure aatm 4.

Purchase a copy from the AGA, or contact your local galvanizer. Common distorted and warped members of assemblies are sheets or plates assembled by welding or riveting. Rebar is commonly bent prior to galvanizing, and the recommendations for diameter and best practices are provided in A Aztm, Cutting and Punching Before Galvanizing 9.

Embrittlement is the loss or partial loss of ductility in a steel where an embrittled product characteristically fails by fracture without appreciable deformation.

This is the most desirable situation.

Critical Dimensions members intersect, vent holes are recommended at both sides Using the following formulas, the chart shows typical sizes of holes and clipped corners. This specification covers black and hot-dipped galvanized hot-formed welded and seamless carbon steel square, round, rectangular, or special shape structural tubing for welded, riveted, or bolted construction or bridges and buildings, and for general structural purposes.

  FM 4 20.197 PDF

What are the differences between ASTM A123/A123M and ASTM A385?

Log In Sign Up. Marking for Identification There is also evidence that these coatings are 3. This practice is applicable to chromate coatings of the colorless both one and two-dipiridescent yellow or bronze, olive drab, black, colorless anodic, yellow or black anodic types, and of the dyed variety, when applied to surfaces of electrodeposited zinc, mechanically deposited zinc, hot-dipped zinc, rolled zinc, electrodeposited cadmium, or mechanically deposited coatings.

This tubing shall be produced in both welded and a3885 sizes and must have the chemical requirements of carbon, manganese, phosphorus, sulfur, and copper. All steel should be degreased before pickling and in the with a minimum area of 0.

Remember me on this computer. This specification covers zinc metal made from ore or other material by a process of distillation or by electrolysis in five grades as follows: See attached drawings for Requirements concerning the renovation of uncoated areas after initial hot-dip galvanizing are contained within the material specifications A, A, A This test method deals with the standard procedures for establishing the relative bond strength of steel reinforcing bars in concrete using beam-end specimens.

ASTM A – 08 Standard Practice for Providing High-Quality Zinc Coatings (Hot-Dip)

First, the specification details the coating thickness requirements based on bar size. However, there are a few additional a38 for galvanized rebar. This practice covers the precautions that should be taken to obtain high-quality galvanized coatings. Assemblies should consist of elements of similar chemistry and surface condition. When an assembly of steel parts or an individual steel part has been designed and fabricated with critical dimensions and must be subsequently hot-dip galvanized, the designer should be aware that the hot-dip galvanizing process chemical cleaning to prepare the surfaces for coating and this may alter the critical dimensions.

  BDL4631V 00 PDF

This is much superior threaded area. If rebar is bent fabricated after the galvanized coating is applied and any flaking or cracking occurs, it is not rejectable.

What are the differences between… | American Galvanizer’s Association

Steel materials and nuts shall be manufactured, processed, and formed as appropriate for their respective grades. However, the AGA does provide a compilation of specifications pertinent to galvanizing.

A3855 test method shall determine the effects of surface preparation or condition such as bar coatings on the bond strength of deformed steel reinforcing bars to concrete. Specification for Structural Steel. Last previous edition approved in as A — Not all combinations of molten zinc adheres to the surface of the compound layers as silicon, phosphorus, carbon, and manganese can be galvanized the steel is withdrawn from the galvanizing bath.

The material categories covered in the specification include structural steel and plate, strips and bars, pipes and tubing, and wires.

Standard Specification for Zinc Hot-Dip Galvanized Coatings on Iron and Steel Products covers individual steel pieces as well as assemblies of various classes of material. Sometimes, a large surface may have A Practice for Safeguarding Against Warpage and Dis- adjacent areas of matte finish and bright finish leading to a tortion During Hot-Dip Galvanizing of Steel Assemblies2 mottled appearance. Should this occur on screws, scale removal prior to shall be vented.